What EN 1154 and the available fire-door documents cover
EN 1154 is the European standard for controlled door closing devices — it defines how a closer is classified and tested, including a durability test. Holding a document that references it is not the same as a given model being certified for a fire-rated opening in your market, and this page sets out which is which for the documents we actually hold.
Published 2026-09-29 · Updated 2026-09-29 · Prepared from our factory catalogue and the documents listed on this site.
What the standard is for
EN 1154 covers controlled door closing devices: how they are classified, what power sizes mean, and how they are tested — including a durability test measured in opening and closing cycles. It is the reference a specification points at when it asks for a closer of a given size and performance.
It is a standard about closers. It is not, by itself, a fire-door approval, and a closer that conforms to it is not thereby approved for every fire-rated opening.
What we hold, and what each document covers
Our certificates page lists the documents we hold, with the models each one names and the scope each one states. Three things about them are worth saying here plainly:
- They are held by or issued to our parent manufacturer, Zhaoqing Gemei Precision Hardware Co., Ltd. They are not certificates issued in the QIHENGDoorControls brand name.
- Each one applies to the models listed in it. Where a document's model list is ambiguous about which of our models it means, we have deliberately not mapped it to a model rather than guessing in our favour.
- A series name is not a certification. Our fire-engineering series is a product family; membership of it is not evidence that a specific model is approved for a specific opening.
What to ask for
- Name the model, the opening and the market. Ask us for the document that covers that combination.
- If we do not hold one that covers it, we will tell you so rather than sending something adjacent.
- Give your own approvals process the document and its stated scope, and let it judge. That is what the scope is for.
Cycle-life figures shown on our model pages come from our own packaging label, which states them as a minimum. They are not a substitute for a test report, and we will send the basis if the figure matters to your specification.
What this is based on
- The certificates and test reports we hold, listed with their scope on our certificates page.
- EN 1154, for what the standard covers. We do not reproduce its text.
Related
InquiryThis is an inquiry, not an order. Nothing is charged online.