The original certificates and test reports on this page name Zhaoqing Gemei Precision Hardware Co., Ltd. as the legal manufacturer or document holder. Certification applies only to the models, samples, standards and limitations stated in each original document.
Our current documents, with the issuer, the number and the models each one actually covers — and, just as importantly, what each one does not cover. Every document is downloadable here, including the test reports behind the certificates.
Which door closer documents does your project need?
Start with the specified standard and the exact model, then read the scope of the supporting document. A listed model, a representative test sample and a certified fire-door assembly are different checks.
- UKCA documents — read the certificate and independent test report; the representative sample has fire-behaviour grade 0.
- EN 1154 documents — read the voluntary verification and its technical file; it does not establish every market-access requirement.
- XF 93 documents — read the Chinese fire-door closer type test; coverage is limited to the mapped G802 model.
For a project quotation, send the model, destination market, required standard and door-assembly specification. For F-071 and G1500, the currently published records do not list the model; ask for document coverage before specifying either.
Request a document check with your quotationUKCA — Certificate of Conformity
- Issued by
- LTC Testing & Certification Limited
- Cambridge, United Kingdom
- Number
- LTC260908-GEM-023
- Standard
- BS EN 1154:1997+A1:2003+C1:2003+C2:2006
- Issued
- 14 September 2026 — 13 September 2031
Models covered
801, 800, 802, 803, 1000, 1100, 1200, 1300, 2000, 2100, 3000, 071, 072, G68, G89, 061, 062
Assessed against BS EN 1154 for controlled door closing devices, with the Construction Products Regulations taken as reference. Testing was carried out by Ningbo Dano Youxin Testing Service (report DN20260911-GEM21-UKCA-CPR), with model 801 used as the representative sample.
What this does not cover. The certificate covers an assessment of technical documentation, not an assessment of the whole production. The tested sample's EN 1154 classification is 3 8 3 0 1 1 — the fourth digit, fire behaviour, is 0, so this testing does not cover fire or smoke door assemblies.
EN 1154 conformity — voluntary certificate
- Issued by
- ICR
- icrqa.com
- Number
- ICR/VC/HE260922
- Standard
- EN 1154:1996+A1:2002+AC:2006
- Issued
- 11 September 2026 — 10 September 2031
Models covered
68, 89, 800, 801, 802, 1000, 1100, 1200, 1300, 2100
Verification against EN 1154, with the Construction Products Regulation (EU) 305/2011 as the referenced legislation. Test report CE-HR20260910-ZQGM-1.
What this does not cover. This is a voluntary certificate. The document states that it does not imply meeting all essential requirements listed in a Declaration of Conformity, and that placing the product on the European market may require an EC/EU-type examination by a Notified Body. The referenced tests were conducted in-house rather than by an independent laboratory. If your project needs Notified Body certification, ask us before specifying — we will tell you plainly what we do and do not hold.
Fire door closer — Chinese national type test
- Issued by
- Sichuan Fire Research Institute of MEM (SCFRI)
- National Fire-Retardant Building Materials Quality Inspection & Testing Center (NFTC)
- Number
- Report 2025210441
- Standard
- XF 93-2004 《防火门闭门器》 (fire door closers)
- Issued
- 18 July 2025 · No stated expiry
Models covered
XF93-4CⅢ (802)
Type test across all applicable clauses of XF 93-2004, tested 26 June – 10 July 2025. The report concludes that every tested item conforms to XF 93-2004 and that the product is judged conforming.
What this does not cover. This is a Chinese national standard for fire door closers and covers one model only. It is not equivalent to EN 1634 or BS 476, which European and UK fire door projects generally require. Do not rely on it for a fire-rated opening outside China without asking us first.
The three documents above are everything we currently hold for these products. If you are used to seeing a longer wall of badges on a supplier's site, that is the difference — we are not showing certificates that have run out.
Our production site has separately been audited by Intertek. That is an assessment of the factory rather than of any product, so it is not listed above as a product certificate.
The PDFs are linked above, with no form in the way. Where a certificate rests on a test report, that report is there too, so you can check the scope yourself rather than take our summary of it.
Need a document for a specific market?
Tell us the model and the country, and we will send the certificate that applies — or tell you straight that we do not hold one for that case. We would rather lose an order than have you find out at inspection.
Request a certificate